![]() ![]() ![]() NOTE: The firmware upgrade utility will not allow you to upgrade from one version of 07.xx.xx.xx firmware to another, even though the controller firmware you are attempting to update to is a later or more recent version. When using the MD Firmware Cross Generation Upgrade Utility, you will have to browse to the location where firmware version 07.35.22.61 was saved instead of using the default directory. Firmware version 07.35.22.61 contains important updates that improve the cache management operation of your MD3000i. When updating your RAID controllers from firmware version 06.xx.xx.xx (Generation 1) to 07.xx.xx.xx (Generation 2), please use the FW version 07.35.22.61 included in this archive instead of version 07.35.22.60 packaged within the MD Firmware Cross Generation Upgrade Utility contained on the Resource CD. Once a controller is running the 07.xx.xx.xx controller firmware the controller firmware should be updated using the firmware download option in MDSM. The utility is installed along with the latest version of the MD Storage Manager. This includes any services dependant on the array, including Microsoft Cluster Services or database applications. The firmware upgrade utility must be used to upgrade the controllers from the 06.xx.xx.xx controller firmware to the 07.xx.xx.xx controller firmware and I/O must be stopped prior to starting the download procedures. ![]()